156
Reference Manual
00809-0100-4811, Rev DA
Appendix A: Reference Data
January 2015
Reference Data
Cx - special configuration (software)
C1 Factory configuration (Configuration Data Sheet required with order, available at www.rosemount.com)
C4 Namur alarm and saturation levels, high alarm
C5 Namur alarm and saturation levels, low alarm
C8
(17)
Low alarm (standard Rosemount alarm and saturation levels)
Qx - special certifications
Q4 Calibration Data Certification
Q8
(18)
Material Traceability Certification per EN 10204 3.1
U1 WHG Overfill Approval. Only available with HART 4-20 mA output (Output Option Code H)
QG GOST Primary Verification Certificate
Consolidate to chamber
(19)
XC Consolidate to chamber
Engineered solutions
Rxxx Engineered Solutions beyond standard model codes (consult factory for details)
(1) Requires external 8-30 Vdc power supply.
(2) Process seal rating. Final rating depends on flange and O-ring selection.
(3) For other materials, consult the factory.
(4) Available in SST. Consult the factory for other materials.
(5) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit.
If tank height is unknown, please round up to an even length when ordering. Probes can be cut to exact length in field. Maximum allowable length is
determined by process conditions.
(6) Available in material 316L and EN 1.4404. For other materials consult the factory.
(7) ASME/ANSI: Raised face type for SST flanges. EN: Type A flat face for SST flanges. JIS: Raised face type for SST flanges.
(8) Available in material 316L. For pressure and temperature rating, see page 124.
(9) Probes are intrinsically safe.
(10) Available for flanged connection.
(11) 3301: valid for probe type 3A, 3B, 4A, 4B, and 4S. 3302: valid for probe type 3B, 4A, 4B, and 4S.
(12) Not available with PTFE covered probes.
(13) Only for Material of Construction code 1 and Probe Type 5A.
(14) Material in accordance with selected material of construction for probe types 2A, 4A, 4B, 4S, and 5A.
(15) Available for SST, Alloy-C-276, and Alloy 400 probes, type 2A, 4A, 4B, 4S, and 5A.
(16) Requires software version 10 or higher.
(17) The standard alarm setting is high.
(18) Option available for pressure retaining wetted parts.
(19) Selecting the XC option code on the Rosemount 3300 Series Guided Wave Radar and the Rosemount 9901 Chamber will result in matching, consolidating,
configuring, and shipping of the two products in one crate. Note that the flange bolts are only hand-tightened. Long rigid single lead probes (> 8 ft/2.5 m)
are shipped separately in order to reduce transportation risk damage.